Description
Product Parameters
Technical Data | ||||
Item | LY1050-EU | LY1050-RS485 | LY1550-EU | |
Battery Parame- ters | System Voltage | 12V | ||
Max Charging Current | 10A | 15A | ||
MPPT Charging Voltage | before boost or equalization charging stage | |||
Boost Voltage | 14.5V@25℃ | |||
Equalization Voltage | 14.8V@25℃(Liquid,AGM) | |||
Float Voltage | 13.7V@25℃ | |||
Low Volt. Disconnect | 10.8~11.8V.soc1~5(default:11.2V) | |||
Overcharge Protect | 15.5V | |||
Temp.Compensation | -4.17mV/K per cell (Boost,Equalization) -3.33mV/K per cell(Float) |
|||
Charging target voltage | 10.0~17.0V(Programmable,default: 14.4V) | |||
Low voltage disconnect | 9.0~15.0V(Programmable,default: 10.6V) | |||
BatteryType | Gel,AGM,Liquid,Lithium(default:Gel) | |||
Max volton Bat.termina | 20V | |||
Panel Parame- ters | Max volt on PV terminal | 45V | 35V | |
Max input power | 130W | 200W | ||
Day/Night threshold | 8.0V | |||
MPPT tracking range | (Battery Voltage + 1.0V)~Voc*0.9*2 | |||
Load | Output Current | 10A | ||
USB interface | 5V,2A | / | 5V,2A | |
Load mode | Always on,Street lamp,User-defind Mode | |||
System Parame- ters | Max tracking efficiency | >99.9% | ||
Max charge conversion | 97.50% | |||
Dimensions | 189*96*53mm | |||
Weight | 420g | |||
Self consumption | 0.2W | |||
Communication | / | RS485 | / | |
Grounding | Common Negative | |||
Power terminals | 8AWG(10mm2) | |||
Ambient temperature | -20~+55℃ | |||
Storage temperature | -25~+80℃ | |||
Ambient humidity | 0~100%RH | |||
Protection degree | IP32 | |||
Max Altitude | 4000m |
ltem | LY2010 | LY3010 | LY2075 | LY3075 | |
Battery Parame- ters | Max Charging Current | 20A | 30A | 20A | 30A |
System Voltage | 12V/24V automatical recognization | ||||
MPPT Charging Voltage | before boost or equalization charging stage | ||||
Boost Voltage | 14.0~14.8V/28.0~29.6V @25℃(default:14.5/29V) | ||||
Equalization Voltage | 14.0~15.0V/28.0~30.0V @25℃(default:148/29.6V) | ||||
Float Voltage | 13.0~14.5V/26.0~29.0V @25℃(default:13.7/27.4V) | ||||
Low voltage disconnect | 10.8~11.8V/21.6~23.6V,AOC1~5(default:11.2/22.4V) | ||||
Low voltage reconnect | 11.4~12.8V/22.8~25.6V(default:12.0/24.0v) | ||||
Overcharge Protect | 15.8/31.3V | ||||
Temp. Compensation | -4.17m V/Kper cell (Boost,Equalization) -3.33m V/K per cell (Float) | ||||
Charging target voltage | 10.0~32.0V(Lithium,default:14.4V) | ||||
Charging recovery voltage | 9.2~31.8V(Lithium,default:14.0V) | ||||
Low voltage disconnect | 9.0~30.0V(Lithium,default:10.6V) | ||||
Low voltae reconnect | 9.6~31.0V Lithium.default:12.0V) | ||||
Battery Type | Gel, AGM,Liquid,Lithium(default:Gel) | ||||
Max volt on Bat. Terminal | 35V | ||||
Panel Parame- ters | Max volt on PV terminal | 95V | 55V | ||
Max input power | 260/520W | 390/780W | 260/520W | 390/780W | |
Day/Night threshold | 3.0~20.0V(default:8.0/16.0V) | ||||
Day/Night delay time | 0~30min(default:0min) | ||||
MPPT tracking range | (Battery Voltage+1.0V)~Voc*0.9*2 | ||||
Load | Output Current | 20A | 30A | 20A | 30A |
Load mode | Always on, Street lamp,User-defind Mode | ||||
System Parame- ters | Max tracking efficiency | >99.9% | |||
Max charge conversion | 98% | ||||
Dimensions(mm) | 189*182*64 | 189*255*63 | 189*182*58 | 189*182*64 | |
Weight | 1Kg | 1.5Kg | 1Kg | 1.3Kg | |
Self consumption | ≤8mA(12V),≤12mA(24V) | ||||
Communication | RS485(RJ11 interface) | ||||
Optional | lOT,Cyber-BT(Internal/External) | ||||
Grounding | Common Negative | ||||
Power terminals | 6AWG(16mm2) | ||||
Ambient temperature | -20~+55℃ | ||||
Storage temperature | -25~+80℃ | ||||
Ambient humidity | 0~100%RH | ||||
Protection degree | IP32 | ||||
Max Altitude | 4000m |
Item | LY4015 | |
Battery Parame- ters | Max Charging Current | 40A |
System Voltage | 24V/48Vautomatical recognization | |
MPPTCharging Voltage | before boost or equalization charging stage | |
Boost Voltage | 28.0~29.6V/56.0~59.2V @25℃(default:29.0/58.0V) | |
Equalization Voltage | 28.0~30.0V/56.0~60.0V@25℃(default:29.6/59.2V) | |
Float Voltage | 26.0~29.0V/52.0~58.0V@25℃(default:27.4/54.8V) | |
Low voltage disconnect | 21.6~23.6V/43.2~47.2v.soc1~5(default:22.4/44.8V) | |
Low voltage reconnect | 22.8~25.6V/45.6~51.2V(default:24.0/48.0V) | |
Overcharge Protect | 31.3/62.3V | |
Temp.Compensation | -4.17mV/K per cell(Boost,Equalization) -3.33mV/K per cell(Float) | |
Charging target voltage | 20.0~64.0V(Lithium,default:29.4V) | |
Charging recovery voltage | 18.2~63.8V(Lithium,default:28.7V) | |
Low voltage disconnect | 18.0~60.0V(Lithium,default:21.0V) | |
Low voltage reconnect | 18.6~62.0V(Lithium,default:22.4V) | |
Battery Type | Gel.AGM,Liquid,Lithium(default:Gel) | |
Max volt on Bat.Terminal | 65V | |
Panel Parame-ters | Max volt on PVterminal | 150V |
Max input power | 1000/2000W | |
Day/Night threshold | 6.0~40.0v(default:16.0/32.0V) | |
Day/Night delay time | 0~30min(default:0min) | |
MPPT tracking range | (Battery Voltage + 1.0V)~Voc*0.9*2 | |
Load | Output Current | 30A |
Load mode | Always on,Street lamp,User-defind Mode | |
System Parame- ters | Max tracking efficiency | >99.9% |
Max charge conversion | 98.70% | |
Dimensions | 189*255*89mm | |
Weight | 2.5Kg | |
Self consumption | ≤8mA | |
Communication | RS485(RJ11 interface) | |
Optional | IOTCyber-BT(Internal/External) | |
Grounding | Common Negative | |
Power terminals | 6AWG(16mm2) | |
Ambient temperature | -20~+55℃ | |
Storage temperature | -25~+80℃ | |
Ambient humidity | 0~100%RH | |
Protection degree | IP32 | |
Max Altitude | 4000m |
Product Features
It comes with a number of outstanding features such as:
- A combination of multiple tracking algorithms enables tracking the maximum power point quickly and accurately
- Innovative Max Power Point Tracking(MPPT) technology,tracking efficiency>99.9% Full digital technology, high charge conversion efficiency up to 98% ILCD display design,read operating data and working condition easily
- Real-time energy statistics function
- 12/24/48V automatic recognition
- Flexible System battery selection:Liquid,Gel,AGM and Lithium
- Extends battery life through accurate remote temperature sensor
- The Controller is protected against over-temperature due to built-in power reduction function
- Four stages battery charging process : MPPT,boost,equalization,float
- Dual automatic protection to avoid exceeding the rated charging power and current
- Multiple load control modes:Always on,Street lamp, User-defind Mode
- Two USB interfaces(only -EU model)
- lOT Wireless communication or Bluetooth communication functions optional
- With the wireless communication function of the loT,the controller can be connected remotely through loT/GPRS
- Monthly charging data can be calculated and displayed by grouping and graphs
- Based RS-485 standard Modbus protocol with RJ11 interface to maximize the communication needs of different occasions.
- Perfect EMC & thermal design
- Full automatic electronic protect function for increased charge controller availability
Structure & Characteristic of LY1050/1550-EU/LY1050-RS485
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Appearance And Installation Dimensions
LY1050/1550-EU/LY1050-RS485
LY2075/2010/3075
LY3010/4010
LY4015
WARNING:Risk of explosion!
- Equalizing flooded battery can produce explosive gases, so well ventilation of battery box is necessary.
- The RS485 interface on this charger is not galvanically isolated and can not be grounded. Do not shortcircuitunused pin(Note NC).
- CAUTION: Please read all instructions and precautions in the manual before proceeding with the installation! lt is recommended to remove the protective film cover from the LCD screen before operation.
- WARNING: The PV-module/array can produce open-circuit voltages in excess of 100 V dc when exposed to sunlight. Pay highest attention to this fact.
- WARNING: Risk of explosion! In case the battery’s positive and negative terminals or leads get ever in touch, i.e. short-circuited, a fire or explosion hazard might get triggered Always pay maximum when handling batteries and related circuits.
- CAUTION:
1. When the controller is not connected with the external temperature sensor the internal temperature of the battery is 25 ℃
2.lf a power inverter is used the system, directly connect the inverter to the battery. Do not connect it to the controller’s load terminals